Autoclaves Ref. Front Loading Autoclaves THS Series

Supplier: Labnics Equipment

SearchProduct details

Safety and ease of operation: Robust chamber and lid. Shiny polished SUS-304 stainless steel chamber and pressed lid with reasonable reinforcements and tested for high water pressure (3.6kg/cm2, twice as high as for safety valve).

Every tray rests at the side stopper and can take heavy loads. The trays can be taken out of the chamber when the autoclave is required to be used without trays. In case of abnormal conditions or faults, the safety devices cut power supply and release the pressure out. Water lack, over pressure, abnormal lid lock system, sensor trouble, etc., are indicated on the panel by error signal with audible alarm.

Heat protection cover of the lid: Even 2 or 3 pieces of 5-liter conical flask can be put directly on the lower drawer tray. 5 operation patterns: Fully automatic operation just by pushing the start key. The set parameters are saved for recall even if the power is cut off.

Sterilization>>Auto exhaust>>Glassware and tools Sterilization>>Natural cooling..........Liquid Sterilization>>Natural cooling>>Warning.....Culture medium Dissolution>>Natural cooling>>Warning...Culture medium Sterilization>>Auto drain>> Air circulating drying (DP models)

Warming system after sterilization: The warming function of the autoclave keeps the sterilized culture medium at an appropriate temperature (40 to 75°C) for its ready use. Soft and safe lid system with safety cover: The lid can be opened and closed firmly with four handles and a self-closing silicone rubber gasket. Operation does not start if all handles are not locked properly.

Electronic and magnetic air exhaust device: Temperature and time free steaming system. Even petri dishes or small items in bags or buckets are exposed to the saturated steam. Control of integrating sterilization temperature: The timer-operation stops while temperature in the chamber comes down more then 1°C below the set temperature and starts again after return. Delay start timer: By this function, operation can be started at 1~99 hours late after you push the start key. For example, if you set the system on Friday evening, operation will start before you arrived at your office on Monday morning and you can readily take out the objects any time you desire.

POA

 

Enquiry about this product:

Complete this form and send it to the supplier of this product for more information and how to order.

Product name Price

Autoclaves
Supplier: Labnics Equipment

Laboratory Autoclave TZQ-24

POA

Autoclaves
Supplier: Labnics Equipment

Laboratory Table Top Autoclaves LPA Series

POA

Add your products to the catalogue »

Directory
Monday, 13 Oct 2008, 05:08 BST
You are here:

About Us Terms Site Map Just Ask Contact ConstructionMall